Home > Btrieve Error > Btrieve Error 11 Pervasive

Btrieve Error 11 Pervasive

Contents

It's a client / server installation. You tried to read or modify a file which was not closed properly after a disk full error. A key segment data type is DATE, TIME, BFLOAT, or AUTOINCREMENT and the segment length is an odd number. Either the key position is greater than the record length or the key position plus the key length exceeds the record length. 028: The record length is invalid The physical record this content

If the bindery context changes, the users and objects made need to be removed and added again under the new context. If for any reason the Winsock driver, Afd.sys, could not send the total amount on a nonblocking socket in a single data packet, Afd.sys would incorrectly report the total bytes sent These parameters are shown below with their default values: SPX VERIFY TIMEOUT=54 SPX LISTEN TIMEOUT=108 SPX ABORT TIMEOUT=540 These three parameters (in the order listed above) have values in a 1:2:10 What is the best way to reconfigure? 10-26-2001 9:23 AM In reply to [email protected] Joined on 08-06-2001 Posts 61 Re: Btrieve Error 11 Reply Contact Several reasons for a dbname to

Pervasive Btrieve Drivers

Occasionally, a corrupt key can cause this status code. The descriptor length (the first two bytes of the data buffer) on the extended operation call must be the exact length of the descriptor. If the file.ddf is examined with a Btrieve utility, the location name for the dictionary files will be x$file.ddf, x$field.ddf, x$index.ddf, instead of the standard file.ddf, field.ddf, index.ddf. Refer to Advanced Operations Guide for more information about RI. 077: The application encountered a wait error This status code is obsolete in MicroKernel versions 7.0 and later.

To Enable Embedded Spaces in Pervasive.SQL 2000i or later: Start Pervasive PSQL Control Center (see "Starting PCC on Windows" on page 3-3 in Pervasive PSQL User's Guide). You could also compare the setup and version of Btrieve with workstations that are working. If it is, change it to read-write. Btrieve Error 12 On this screen there is a field called internal network number.

Reconfigure Btrieve with both a smaller /P configuration option (to allocate more buffers) and a larger /M option (to increase the cache allocation). 048: The alternate collating sequence definition is invalid Pervasive Btrieve Database Manager The links below are for Btrieve error codes. All rights reserved.Unauthorized reproduction or linking forbidden without expressed written permission. If the error persists, there may be system corruption; try to clear the system by rebooting, and then try the operation again. 080: The MicroKernel encountered a record-level conflict The MicroKernel

Close Box Join Tek-Tips Today! Btrieve Error 46 To start viewing messages, select the forum that you want to visit from the selection below. The application tried to unlock a single-record lock with a multiple-record lock or vice-versa. 082: The MicroKernel lost positioning When performing a Get Next or Get Previous operation on a key Anyone have any clue at all??

Pervasive Btrieve Database Manager

The handle table is managed dynamically by the engine. Increase the setting for this component. Pervasive Btrieve Drivers If an application opens a file in any mode other than Exclusive, all other applications receive this status code when they try to open the same file in Exclusive mode. Btrieve Error 161 Return to top Status 5 This status code indicates that the MKDE cannot update the record because the record has a key field that contains a duplicate key value.

In addition, if you are using AutoMode, it is necessary to establish logical position (GetLast, GetFirst, GetEqual, etc.) before making the call to Init. 063: The data buffer parameter specified on http://hammerofcode.com/btrieve-error/btrieve-error-2301-pervasive.php Reply With Quote 08-20-13,12:11 #5 kenb View Profile View Forum Posts Registered User Join Date Aug 2013 Posts 5 Error 11 The function executor opens the file correctly from the workstation. You attempted to include a file in continuous operation, but the file is already in continuous operation. Make sure both of the client configuration options, Access 4 Use Local MicroKernel Engine or Access 4 Use Remote MicroKernel Engine are enabled. Btrieve Error 3012

Recover the file according to the instructions in Pervasive PSQL User's Guide. 023: The position block parameter is not 128 bytes long This status code is obsolete in Btrieve language interface NT has a utility called Security Auditing that may be useful if the server is suspected as being the cause of returning Status Code 94. How does the application try to open the file (Btrieve, ODBC, etc)? have a peek at these guys This number MUST be unique on each machine.

One possible cause of this status code is an application that continues to open additional files without closing the data files that it has already opened. Pervasive Error Code 11 When using a 9.x or higher engine, you cannot perform a write operation such as insert or delete on a 5.x format file. 047: The number of files opened exceeds the Instead, it returns this status code, and the server-based application must retry later. 078: The MicroKernel detected a deadlock condition The application should clear all resources by aborting, ending the transaction,

When the file is reopened, the Btrieve engine detects that the continuous ops flag is set and looks for the delta file.

eg d:\scala\hlp\gl and not \\servername\volumename\directory. Posts: 3 Re: Btrieve Error 11 Reply #2 - 05/16/08 at 08:41:34 You are correct. When the same file is opened multiple times, the MicroKernel uses only one operating system handle. The keybuffer on the Btrieve create operation API (opcode 14) is set properly to create a file over an existing file.

Patch the server and workstation as described in the document Installing Btrieve for Scala. Posts: 3 Btrieve Error 11 05/15/08 at 22:55:12 Have a workstation that returns a Btrieve error 11 when attempting to start DBA. TCP/IP timeout errors On NT4 Check that you have service pack 3 installed (There is a known problem with this in ServicePack2) When a Winsock application calls one of the Winsock http://hammerofcode.com/btrieve-error/btrieve-error-161-pervasive.php Part way through data verificationthe process it stopped.3.

The application attempted to perform a Write operation on a file that is flagged read-only by the operating system. BSPXCOM does not detect this, and sends out the incorrect address in its SAP packets, resulting in incorrect information in the bindery. What happens if you remove the HOSTS entry? Once the engine completes the roll-in, it deletes the delta file. 089: A name error occurred This status code is obsolete in MicroKernel versions 5.0 and later.

This limit is smaller for smaller page sizes. If it loads, then create a new icon pointing to that executable. Uninstall the Scala client by going into control panel/add-remove programs. Right-click on the engine name and click Properties.

There is a malfunction that the MicroKernel cannot specifically detect or from which the MicroKernel cannot recover. It always reserves five empty buffers for index manipulation. In a Get Next Extended, Get Previous Extended, Step Next Extended, or Step Previous Extended operation, the number of records satisfying the filtering condition is less than the number of specified Return to top Status 91.

You can write a subroutine to make this setting (see the ACL Programmers Reference manual, SETREGISTRY) and have the _SysRoot:ACL\StnSetup.ACL execute (USE) your subroutine. Return to top Status 94. Files being accessed must be flagged for read/write access. So, in addition to the network users having permission to the directories where the files being accessed reside, the 'System' user must also have 'full control' permissions.

The maximum number of keys is 119 for all file formats and page sizes. The Readme included with the Novell Client32 for Win95 indicates that this patch fixes long file name resolution problems, but this also addresses "status 11 and status 12 in a DOS To resolve, fill the KeyBuffer with the same fill char type as the field. 005: The record has a key field containing a duplicate key value The MicroKernel cannot add or The MicroKernel tried to open files bound to too many MicroKernel databases.

I did the check on the database and found that the current database is not consistent with dbnames.cfg.