If the error persists, there may be system corruption; try to clear the system by rebooting, and then try the operation again. 080: The MicroKernel encountered a record-level conflict The MicroKernel Drop the key, then add it again. Either the address is outside the file boundaries, or it is not on a record boundary within or on a data page, or the record at the specified address has been For example, in a data files with 4096 byte page size you are limited to 119 index segments per file. this content

Asegure de tener por lo menos 1MB libre en disco duro. Check the validity of the filename. 035: The application encountered a directory error Either a Get Directory operation specified a drive that does not exist, or a Set Directory operation specified If you are working in the Microsoft Terminal Server environment: Approximately 5 users can work in a Windows application on 2 different Terminal Servers that are connected to a primary Windows I have installed TAS fresh on a new pc, and then done a full restore from a working backup into a new data folder.

Btrieve Error 9

A likely scenario is that data created by a new server engine is later used by an earlier Workgroup engine. An unsupported DDF Creation utility called DDL Services (DDLSVCS.DLL) created the DDFs. You tried to open a data file with RI (Referential Integrity) definitions that are bound to a MicroKernel database, and the table to which the file is bound was not found Privacy Policy Site Map Support Terms of Use Btrieve Error Codes 001 - 199 ← Pervasive PSQL MicroKernel (Btrieve) Database Engine Status Codes This section describes status codes that the MicroKernel

Files being accessed must be flagged for read/write access. A key segment data type is NULL INDICATOR SEGMENT and the segment length is not 1. Because this would occupy the MicroKernel and lock out other users who might be trying to release the requested resource, the MicroKernel does not perform the wait. Btrieve Error 11 A key segment data type is CURRENCY or TIMESTAMP and the segment length is not 8.

For example: The application attempts to perform a Step operation on a key-only file. If the data file has RI definitions, the DBNAMES.CFG file must be in the location specified in the DBNames Configuration Location option in the server configuration settings. Using a 5x engine to open the file returns status 42 - a file previously opened in accelerated mode was not closed. There may two solutions: Btrieve File handle configuration may be set incorrectly in BTI.CFG.

For pre-v6.0 data files that are larger than 768 MB, there is a conflict among locking mechanisms. Btrieve Error 35 It is caused by a mismatch of two fields at the char level. The audits can them be reviewed and should provide information on what permissions need to be adjusted to resolve Status Code 94. Your application can retry the operation until the conflict is resolved (when the competing application releases the lock your application requires).

Btrieve Error 161

This increases the amount of time the SPX session remains connected and reduces the likelihood of receiving an unexpected Status Code 95. If you receive this status code and you suspect that the header page of the source file is damaged, recover the file as described in Advanced Operations Guide. Btrieve Error 9 An application tried to extend a file that had already been extended; you can only extend a file once. 032: The file cannot be extended The MicroKernel must create an extension Btrieve Error 3006 Patch the server and workstation as described in the document Installing Btrieve for Scala.

Check for a disk hardware failure. 018: The disk is full The MicroKernel can return this status code in the following situations: The disk is full and the MicroKernel cannot expand news You attempted to open a local file with a Workgroup engine that isn't the designated Gateway engine for the file. Multiple NIC (Network Interface Cards): A routing problem between multiple NICS can cause Status Code 20. Your application tried to open a file in MicroKernel v5.x format using a v5.x MicroKernel; however, that same file was previously accessed by a v6.0 or later MicroKernel, which failed to Btrieve Error 2301

Electronics Btrieve Motorcycling Software If you like my site and want to support me, click on few ads. Refer to the Advanced Operations Guide for more information about bound files. 067: The MicroKernel cannot open the SQL data dictionary files The MicroKernel returns this status code for the following If you are performing an Update operation, there are two possible causes for this status code: You attempted to change the value of a primary key. have a peek at these guys Start by asking a few simple questions like: *"Does it occur for every user?," *"Does it occur on every workstation?," and *"Does it occur for every user on every workstation?" Because

Join & Ask a Question Need Help in Real-Time? Btrieve Error 2 Once the engine completes the roll-in, it deletes the delta file. 089: A name error occurred This status code is obsolete in MicroKernel versions 5.0 and later. Borra todos los archivos con una extensión PRE del programa y de la carpeta de archivo de datos.

The status 22 is usually caused when the DDF definition doesn't accurately describe the Btrieve files.

DacEasy Nómina Sistema de nómina de pago para empleados, expanda su negocio. Make sure the filename or pathname is valid for the environment. An application running on a 9.x or higher engine attempts to create a format file prior to 6.x (0600). 042: A file previously opened in Accelerated mode was not closed This Btrieve Error 20 You must ensure that the username you use to log in to your workstation or into the preferred server exists on the Btrieve server, and the username has the appropriate rights

When a file is opened in Accelerated mode, the MicroKernel reserves one of its cache buffers for the file. To avoid receiving this status code, you must set a higher value for the number of databases that the MicroKernel can open. The file could not be opened in any mode if this happened, it is a bug and should not occur if you are using newer than 5.10 version of Btrieve. - http://hammerofcode.com/btrieve-error/btrieve-error-73.php See Create (14) and Create Index (31), both in Btrieve API Guide, which is part of the Pervasive PSQL Software Development Kit (SDK).

The links below are for Btrieve error codes. You may receive status 2 or corruption on very busy SMP boxes, when a user is deleted from the Btrieve Monitor and the user immediately reopens the files. NOTE: Previously, accessing a 6.x file with a 5.x engine returned Status 2: "the application encountered an I/O error". 031: The file is already extended This status code is obsolete in The number of records to be retrieved is greater than the number of records present in the file that satisfy the filter condition.

One file is open and in Continuous Operation mode, causing the MicroKernel to generate a delta file (for example, INVOICE.^^^). Check the first two bytes returned in the data buffer for the number of records that were retrieved. 061: The work space is too small The Get Next Extended, Get Previous Spam Profanity Threats/Abuse Inappropriate Virus/Danger Broken Links Other Back to search results [14] PRE-IMAGE OPEN ERROR Btrieve error opening DRecBf [14] PRE-IMAGE OPEN ERROR Btrieve error opening DRecBfAnybody seen this error? Imagine you're explaining something to a trusted friend, using simple, everyday language.

Change the setting to "off" if your applications do not allow embedded spaces in file names. You set the Create File Version value to v9.0, and you attempted to use one of the new Pervasive PSQL v10.10 data types, such as GUID. If the bindery context changes, the users and objects made need to be removed and added again under the new context. When you are using the Btrieve Requester to access the MicroKernel, the Requester waits and retries if a requested resource is locked.