Home > Btrieve Error > Btrieve Error 81

Btrieve Error 81

Contents

More Actions Notify me of new answers I can answer People come to Accountants Community for help and answers—we want to let them know that we're here to listen and share On NetWare 4.1x servers this can also be done using the SERVMAN.NLM utility. Therefore, the MicroKernel Database Engine performs a login using the username and password passed to it via the 32-bit Btrieve Requester. For details on this error condition, press for Help ©¶ ©¶ 4. this content

It is reset when responses resume. When no other word will do, explain technical terms in plain English. Change the CONFIG.SYS file in the ROOT directory so that the number on *FILEs=* line is increased, (reboot the PC!) 93 INCOMPATABLE LOCK TYPE: An attempt was made to lock a file Yes No moderator_mel Employee Add a comment Comment No answers have been posted This post has been closed and is not open for comments or answers.

Erro Btrieve Status 81

check that the server volume is not full. Due to the failing word index updates, search results are not correct, specifically, you will find that the NEO word search only finds messages that you received or sent prior to Ask yourself what specific information the person really needs and then provide it.

Status Code 20 with a delay indicates a communication problem. Both record and file locks can be increased using the Console SET command. All rights reserved. Btrieve Error 11 Ensure all users are logged out, and run the CLEAR utility. 8 INVALID POSITIONING:  An attempt was made to update a record without having retrieved the record first. 43 INVALID RECORD ADDRESS: The

Check to see that the Btrieve server is actually running Use the Btrieve monitor on the server to see that you have not reached your maximum limit of remote connections If Btrieve Error 161 These parameters are shown below with their default values: SPX VERIFY TIMEOUT=54 SPX LISTEN TIMEOUT=108 SPX ABORT TIMEOUT=540 These three parameters (in the order listed above) have values in a 1:2:10 In the main directory type DELETE*.TRN, and check BTRIEVE is being loaded correctly before GILTS boots up. 37 TRANSACTION IS ACTIVE: A transaction was started whilst another was already active.  Solution: Exit and To get the latest build of NEO Pro click here.

If not, change the network number in the workstation to match the server. Btrieve Error 35 Another version can cause Status Code 20. Summary of Btrieve error codes 1: The operation parameter is invalid. 2: The application encountered an I/O error. 3: The file is not open. 4: The application cannot find the key NT has a utility called Security Auditing that may be useful if the server is suspected as being the cause of returning Status Code 94.

Btrieve Error 161

Winsock.dll and wsock32.dll: For a TCP/IP stack the original version of Winsock.dll and wsock32.dll should be used. Files being accessed must be flagged for read/write access. Erro Btrieve Status 81 I tried repairing the pervasive 9 install on my workstation, but after that the above error message is still displayed, and my test application still returns error 81. Btrieve Error 3006 In Win95 : the amount of retries may be increased editing the registry in : HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\VxD\MSTCP MaxConnectRetries = Data Type: DWORD Valid Range: 32-bit number This specifies the number of times

By default, these services use the 'System' user. news The default is 00000000 and if you have more than one server, this could cause routing problems. My guess is that the code executes so fast on newer CPUs that the system never has enough time to write a lock file to disk? TcpMaxDataRetransmissions Key: Tcpip\Parameters Value Type: REG_DWORD - Number Valid Range: 0 - 0xFFFFFFFF Default: 5 This parameter controls the number of times TCP will retransmit an individual data segment (non connect Btrieve Error 2301

RCONSOLE is a good test for SPX 1) Run RCONSOLE on a workstation, 2) Let it run the length of time it takes for the Btrieve application to get the status Workstation Attributes If any user gets Status Code 94 on one or a few workstations and those same users do not get the error on other workstations, that indicates component (.dll This is relater to new, MultiEngine Filesharing Mode where Btrieve keeps track of other engines with the .LCK files. have a peek at these guys The initial timeout value is three seconds.

Resolution A corruption in the word index results in Database Error 81's on a Word Index Update that causes the word index update to fail. Btrieve Error 2 Return to top Status 14 This status code tells you that there is insufficiant disk spae on the server to create a pre-image file. Page url: http://www.cassoftware.com/tas/manual/btrieveerrorcodes.htm ImageSlideShow requires Javascript HomeAbout UsAbout usBook a DemoContact usAssociatesTestimonialsProductsKISKIS BenefitsKIS FeaturesKIS ScreenshotsBook a DemoKs4Postal CodesGILTS SupportGILTS - Utilities & fixesGILTS - BTRIEVE error codesGILTS - Error 30 recoveryGILTS

Bindery problem with NW 4.10: In a NetWare 4.10 environment, there is an issue with a bindery problem where BSPXCOM receives the wrong address from NetWare.

If you are running a Netware server, try to patch your server so that you have the latest clib.nlm version. There may be other symptoms because an incorrect response will have an undetermined effect on the application. If you are going to keep using the ActiveX controls, I would suggest using the Pervasive ActiveX Controls instead of the Smithware version. Btrieve Error 20 Click Here KIS Brochure To Download the latest KIS Brochure to read at your leisure.

Return to top Status 94. Other causes of status 95s are related to communication problems on the network. Returned as COBOL status: 9/213 Parent topic: 80 - 99 Send feedback about this topic Why do we get a Btrieve error 81 accessing LICENSE.DAT? http://hammerofcode.com/btrieve-error/btrieve-error-73.php The other obvious questions is why are you using the Smithware ActiveX Controls?

Ask your question to the community. This could be the result of a network communication problem. Answer guidelines Saved to your computer. I tried setting the open mode to read only in my code but that made no difference.Here is my Visual Studio console project code: using System;

using System.Collections.Generic;

using System.ComponentModel;

using

Spam Profanity Threats/Abuse Inappropriate Virus/Danger Broken Links Other Back to search results Btrieve 81 error Get Btrieve 81 lock error. To resolve this problem, increase the SPX timeout parameters in the Windows NT registry under the following key: HKEY_LOCAL_MACHINE/SYSTEM/CurrentControlSet/Services/ NwLink SPX/ Parameters connection timeout initial retransmission timeout keep alive timeout Double Page 1 of 1 (6 items) 800.287.4383 | Privacy Policy | Terms & Conditions © 2013 Actian Corporation. winsock.dll version 4.00.950 works wsock32.dll version 4.00.951 works TIP Status Code 20 From Windows NT/95 Workstations to Btrieve for NT Server: Run "ipxroute config" from a DOS prompt on the server

The Maximum Connection must be set to at least 2.