Home > Btrieve Error > Btrieve Error

Btrieve Error

Contents

Btrieve Error Codes 001 - 199 ← Pervasive PSQL MicroKernel (Btrieve) Database Engine Status Codes This section describes status codes that the MicroKernel returns. In key-only files, you receive this status code if the record is moved in the file b-tree after being read and before being updated or deleted. This can be caused by a program with corrupt files, a registry that has become corrupt, or an operating system that is not properly updated. This might work at first but after awhile you will find that you have to restart the application more than a few times. this content

Editing the registry should only be done by an experienced system engineer. So, in addition to the network users having permission to the directories where the files being accessed reside, the 'System' user must also have 'full control' permissions. IPX/SPX, Timeout errors When running a Btrieve application on a Windows NT workstation using the Btrieve requester a Status Code 95, "The session is no longer valid," may be returned when You tried to read or modify a file which was not closed properly after a disk full error.

Btrieve Error 161

An extended file can consist of a base file and up to 31 extension files. Accessing Status Codes From Applications Are you a developer that wants a way to access status code information directly from within your application? In some environments, you can restrict the amount of disk space available to each user.

You set the Create File Version value to v9.0, and you attempted to use one of the new Pervasive PSQL v10.10 data types, such as GUID. The error results from a missing MSDADC.DLL on the deployment machine. Perform a Get or Step operation to establish the current position. Btrieve Error 35 The number of segments specified in the data buffer exceeds the limit for maximum segments.

Right-click on the engine name and click Properties. Btrieve Error 3006 On a Stat Extended operation, the signature field in the data buffer is not set to 0x74537845, the subfunction field is not set to 0x00000001, or the Pervasive PSQL Explorer field Things to look at Network Attributes: Regardless of operating systems involved, the following guidelines apply: The user name should NOT be "Admin" or "Supervisor," and the password should not be left The pre-image file is damaged and the integrity of the data file cannot be ensured.

An application tried to extend a file that had already been extended; you can only extend a file once. 032: The file cannot be extended The MicroKernel must create an extension Btrieve Error 2 Back to index Copyright © Madis Kaal 2000- Electronics Btrieve Motorcycling Software If you like my site and want to support me, click on few ads. An application running on a 9.x or higher engine attempts to create a format file prior to 6.x (0600). 042: A file previously opened in Accelerated mode was not closed This The Readme included with the Novell Client32 for Win95 indicates that this patch fixes long file name resolution problems, but this also addresses "status 11 and status 12 in a DOS

Btrieve Error 3006

When you receive this status code on an Update or Delete operation, it usually means that the file is damaged, and you must recreate it. DDL Services has a known bug that causes the system table to be populated with incorrect data. . Btrieve Error 161 Note The same named database cannot exist on two servers on the same network. Btrieve Error 2301 The length of a key segment must agree with its key type if the key type implies a length (for example, an integer key must have a length evenly divisible by

These files are: 'W32mkdex.exe' 'W32mkrcx.dll' 'Wbtrv32x.dll' Make a copy of these three files within the NEO directory and make sure they are named as the following: 'W32mkde.exe' 'W32mkrc.dll ' 'Wbtrv32.dll'Once the news It is often a good idea to try other SPX applications. This status code indicates that the application encountered a directory error. Reconfigure Btrieve with both a smaller /P configuration option (to allocate more buffers) and a larger /M option (to increase the cache allocation). 048: The alternate collating sequence definition is invalid Btrieve Error 11

Return to top Status 94. You attempted to create a file with the Replace option, and a bound MicroKernel data file with the same name and location already exists. If the file.ddf is examined with a Btrieve utility, the location name for the dictionary files will be x$file.ddf, x$field.ddf, x$index.ddf, instead of the standard file.ddf, field.ddf, index.ddf. have a peek at these guys The application tried one of the following: Applied a no-wait lock on a record that is currently locked by another application Tried to access a file in a no-wait transaction while

For pre-v6.0 data files, there is a large pre-image file inside a transaction, and there is not enough disk space for a write to the pre-image file. Btrieve Error 20 Go to the directory where the file you attempted to open resides. For the transactional interface, the maximum number is 204 for a page size of 4,096, and 420 for page sizes 8,192 and 16,384.

Btrieve status codes Below are all Btrieve status codes that I know about, click on any of these to get a description and more information about the error code. 0 1

Expand the Local Client node. Use a NET START FULL to get a full redirector in the DOS client mode. Make sure both of the client configuration options, Access 4 Use Local MicroKernel Engine or Access 4 Use Remote MicroKernel Engine are enabled. Btrieve Error 22 Contact Scala support Return to top Status 11 This status code indicates that the file name specified does not conform to the file-naming conventions.

The MicroKernel encountered an error while writing the directory structure to disk prior to creating the expanded file partition. RCONSOLE is a good test for SPX 1) Run RCONSOLE on a workstation, 2) Let it run the length of time it takes for the Btrieve application to get the status The retransmission timeout is doubled with each successive retransmission in a given connect attempt. http://hammerofcode.com/btrieve-error/btrieve-error-73.php To initiate the roll-in of an existing delta file, the associated data file must be opened.

Check BTI.CFG for file handle setting (/h: and /f:) and increase those values. Right-click the file then click Properties. Make sure that the READ ONLY attribute is not set on the files in question. However, the MicroKernel detected that the existing bound file was out of sync (that is, an attempt to open the existing file would have returned this same status code).

For the recovery solution for this instance, refer to Microsoft Knowledgebase Article 190162, "Terminal Server and the 2048 Open File Limitation." 012: The MicroKernel cannot find the specified file Check that This increases the amount of time the SPX session remains connected and reduces the likelihood of receiving an unexpected Status Code 95. Check the validity of the filename. 035: The application encountered a directory error Either a Get Directory operation specified a drive that does not exist, or a Set Directory operation specified This can be due to old workstation drivers for the network, old LAN card drivers at the workstation or server, bad hardware (usually the LAN cards at the workstations or server),

There may be other symptoms because an incorrect response will have an undetermined effect on the application. Correct the buffer length or the number of records. 064: The filter limit has been reached The MicroKernel returns this status code for the following reasons: During a Get Next Extended, Refer to Advanced Operations Guide for more information about recovering damaged files. The links below are for Btrieve error codes.

Expand Engines and find the desired engine name. This status code usually means that the MicroKernel was unable to save or restore the memory mapping register context, indicating an incompatibility with another application that uses expanded memory. 058: The The application attempted to perform a Write operation on a file that is flagged read-only by the operating system. If it is then try the following solution.

Click Compatibility. If you are running an application in a client/server environment and also need to access files located on a local drive: Make sure the Btrieve Requester is loaded. Change the setting to "off" if your applications do not allow embedded spaces in file names. A key segment data type is BINARY ("Use Old Style Binary Data Type" flag is "on") and the segment length is odd. 030: The file specified is not a MicroKernel file

You have either attempted to open more handles than the MicroKernel is configured to support, or the MicroKernel attempted to open more files than the operating system allows. Before attempting any of the below solutions, please reboot your system to be sure the error was not caused by an incidental shutdown of the database engine. In a Get Next Extended, Get Previous Extended, Step Next Extended, or Step Previous Extended operation, the number of records satisfying the filtering condition is less than the number of specified While using an earlier version of Btrieve, you opened a file created by a later version that has a format incompatible with the earlier version.